|
Title |
Heat treatment effect on NITI files fatigue resistance
|
|
Authors |
Anjali Bichpuriya1,*, Fiza Qureshi2, Saara Khiyani3, Vrishali Radke4, Riddhi Agrawal5 & Devaguptapu VV Krishna Sreenija6
|
|
Affiliation |
1Department of Conservative Dentistry and Endodontics, Swargiya Dadasaheb Kalmegh Smruti Dental College and hospital, Nagpur, Maharashtra, India; 2Department of Oral Surgery, Maitri college of Dentistry and Research Centre, Durg, Chhattisgarh, India; 3Department of Conservative Dentistry and Endodontics, Guru Govind Singh College of Dental Science and Research centre, Burhanpur, Madhya Pradesh, India; 4Consultant Dentist, Ram Nagar, Supela, Bhilai, Chhattisgarh, India; 5Department of Conservative dentistry and endodontics, RKDF Dental College and Research Centre, Bhopal, Madhya Pradesh, India; 6Department of Conservative Dentistry and Endodontics, Anil Neerukonda Institute of Dental Sciences, Visakhapatnam, Andhra Pradesh, India; *Corresponding author
|
|
|
Anjali Bichpuriya - E-mail: dranjalibichpuriya999@gmail.com Fiza Qureshi - E-mail: qureshi.fiza96@gmail.com Saara Khiyani - E-mail: drsaarak@gmail.com Vrishali Radke - E-mail: vrishali.radke@gmail.com Riddhi Agrawal - E-mail: agrawalriddhi98@gmail.com Devaguptapu VV Krishna Sreenija - E-mail: devaguptapusreenija@gmail.com
|
|
Article Type |
Research Article
|
|
Date |
Received February 1, 2026; Revised February 28, 2026; Accepted February 28, 2026, Published February 28, 2026
|
|
Abstract |
The impact of autoclave sterilization on the cyclic fatigue resistance (CFR) of three heat-treated NiTi systems used in endodontics is concern. Therefore, it is of interest to compare the cyclic fatigue resistance (CFR) of three heat-treated NiTi systems (ProTaper Gold, Edge Taper Platinum and HyFlex EDM) following autoclave sterilization. Hence, ninety files were tested under artificial canals after 0, 3 and 5 autoclave cycles. Results showed HyFlex EDM had the highest CFR at all intervals, followed by Edge Taper Platinum and ProTaper Gold. Autoclave sterilization significantly improved CFR for HyFlex EDM and Edge Taper Platinum, while ProTaper Gold showed no significant change. SEM analysis revealed fewer machining defects in HyFlex EDM. Thus, insights into the cyclic fatigue resistance (CFR) of three heat-treated NiTi systems after autoclave sterilization, contributing to the understanding of the performance of endodontic files under stress. |
|
Keywords |
Cyclic fatigue, NITI endodontic files, heat treatment, autoclave sterilization, methodological heterogeneity, files systems
|
|
Citation |
Bichpuriya et al. Bioinformation 22(2): 1216-1219 (2026)
|
|
Edited by |
Ritik Kashwani
|
|
ISSN |
0973-2063
|
|
Publisher |
|
|
License |
This is an Open Access article which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. This is distributed under the terms of the Creative Commons Attribution License.
|
|
|
|