HOME   |    PDF   |   


Title

Accuracy of full-arch prostheses fabricated through fully digital, hybrid or conventional workflows: A 3D superimposition analysis

 

Authors

J.  Srilakshmi1,*, Ramanpreet Kaur2, Ankit Malu3, Afroz Anjum4, Saba Anjum5 & M.K Sufiyan6

 

Affiliation

1Department of Prosthodontics and Implantology, Rajarajeswari Dental College & Hospital, Bangalore Karnataka, India; 2Department of Prosthodontics, Oral health sciences center, Post Graduate Institute of Medical Education & Research, Chandigarh, India;  3Department of Oral and Maxillofacial Surgery, Consultant Surgeon, Deenanth Manageshkar Hospital, Pune, Maharashtra, India; 4Private Practioner, Hadad medical and dental center, Abudhabi, UAE;  5Private Practitioner, Plus Dental Center, Kuwait; 6Private Practitioner, Kidzsmile Dental Center, Kuwait; *Corresponding author

 

Email

J.  Srilakshmi - E-mail: drsrilakshmi.j@gmail.com

Ramanpreet Kaur- E-mail: dhindsar836@gmail.com

Ankit Malu - E-mail: ankitmalu@gmail.com

Afroz Anjum- E-mail: dr.afrozanjum@gmail.com

Saba Anjum- E-mail: drsabaprostho@gmail.com

M.K Sufiyan - E-mail: drsufiyanmk@yahoo.com

 

Article Type

Research Article

 

Date

Received July 1, 2026; Revised July 31, 2026; Accepted July 31, 2026, Published July 31, 2026

 

Abstract

Achieving passive and accurate fit of full-arch implant-supported prostheses remains challenging because cumulative fabrication errors can compromise clinical outcomes. Therefore, it is of interest to compare the trueness and precision of full-arch prostheses fabricated using fully digital, hybrid and conventional workflows. Thirty maxillary full-arch frameworks (n = 10/group) were fabricated on a six-implant reference model and evaluated using three-dimensional superimposition, linear interimplant discrepancy and single-screw passive-fit testing. The fully digital workflow demonstrated the highest trueness and precision (41.8 ± 8.6 µm), followed by the hybrid (58.7 ± 10.9 µm) and conventional (86.4 ± 18.7 µm) workflows, with significant intergroup differences (p < 0.001). Thus, data shows that fully digital workflow produced the most accurate and reproducible prostheses, while the hybrid workflow was a clinically reliable alternative to the conventional technique.

 

Keywords

Digital workflow, full-arch prosthesis, implant prosthodontics, trueness, precision, computer-aided design /computer-aided manufacturing (CAD/CAM)

 

Citation

Srilakshmi et al. Bioinformation 22(7): 4122-4127 (2026)

 

Edited by

Hiroj Bagde

 

ISSN

0973-2063

 

Publisher

Biomedical Informatics

 

License

This is an Open Access article which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. This is distributed under the terms of the Creative Commons Attribution License.