HOME   |    PDF   |   


Title

Efficacy of nanocoated implant surfaces in osseointegration

 

Authors

S. Ramesh Raja1,*, Saloni Bharti2, P. Gladys Tryphena3, Mohit Bansal4, Rahul Maurya4 & S Aswathi5

 

Affiliation

1Department of Prosthodontics, Rajas Dental College and Hospital, Kavalkinaru, Tirunelveli, India; 2Department of Dentistry, ESIC Medical College and Hospital, Bihta, Patna, India; 3Department of Periodontics, Madha Dental College and Hospital Kundrathur, Chennai, Tamil Nadu, India; 4Department of Periodontology, Uttar Pradesh University of Medical Sciences, Saifai, Etawah, Uttar Pradesh, India; 5Department of Periodontics, KMCT Dental College, Mukkam, Calicut, Kerala, India; *Corresponding author

 

Email

S. Ramesh Raja - E-mail: ramsking80@gmail.com; Phone: +91 9159397860
Saloni Bharti - E-mail: drsalonibharti2424@gmail.com; Phone: +91 7091655625
P. Gladys Tryphena - E-mail: tryphenagladys@gmail.com; Phone: +91 7845052749
Mohit Bansal - E-mail: bansalmohit877@gmail.com; Phone: +91 8076259412
Rahul Maurya - E-mail: rahulmaurya007.rockstar@gmail.com; Phone: +91 7355942079
S. Aswathi - E-mail: aswathisujil@gmail.com; Phone: +91 9895529513

 

Article Type

Research Article

 

Date

Received August 1, 2026; Revised August 31, 2026; Accepted August 31, 2026, Published August 31, 2026

 

Abstract

The goal of ensuring predictable and fast integration of the ossicles, especially in compromised bone situations, demands the never ending growth in dental implant surface technology. Therefore, it is of interest to assess the clinical effectiveness of a novel nano hydroxyapatite/zirconia (n-HA/ZrO2) coated implant surface against a conventional sandblasted, large-grit, acid-etched (SLA) one. Hence, eighty-six patients participated in having a test (n-HA/ZrO2) or control (SLA) implant in the mandible under the arch with results measured in terms of implant stability and marginal bone levels at six months. The nanocoated group had much higher Implant Stability Quotient (ISQ) at 3 and 6 months (p<0.001) and also much lower mean marginal bone loss (p<0.001). Thus, data shows that n-HA/ZrO2 nanocoated surface proves to be very effective in the promotion of early outcomes of the osseointegration process, which results in the achievement of good implant stability and preservation of the peri-implant bone.

 

Keywords

Dental implants (DI), osseointegration, nano coating, hydroxyapatite, zirconia, randomized controlled trial (RCT)

 

Citation

Raja et al. Bioinformation 22(8): 4882-4886 (2026)

 

Edited by

Rashmi Laddha

 

ISSN

0973-2063

 

Publisher

Biomedical Informatics

 

License