Title |
Comparative evaluation of crestal bone loss around platform-switched and platform-matched implants: A prospective radiographic study
|
|
Authors |
Jay Gohil1,*, Anshit Babel2, Afroz Anjum3, Devanshi Sharma2, Meetu Rani4 & Divyesh Shetty5
|
|
Affiliation |
1Department of Prosthodontics and Crown & Bridge, K. M Shah Dental College and Hospital, Sumandeep Vidyapeeth deemed to be University, Waghodia, Vadodara, Gujarat, India; 2Department of prosthodontics and Crown & Bridge, Geetanjali Dental and Research Institute, Geetanjali University, Udaipur, Rajasthan, India; 3Private Practioner, Hadad Medical and Dental Center, Abudhabi, UAE; 4Department of Orthodontics, Eklavya Dental College and Hospital, Kotputli, Rajasthan, India; 5Department of Oral and Maxillofacial Surgery, Srinivas Institute of Dental Sciences, Mangalore, Karnataka, India; *Corresponding author
|
|
|
Jay Gohil - E-mail: jagohil92@gmail.com
|
|
Article Type |
Research Article
|
|
Date |
Received August 1, 2026; Revised August 31, 2026; Accepted August 31, 2026, Published August 31, 2026
|
|
Abstract |
Marginal crestal bone stability influences the long-term biological and esthetic success of implant-supported restorations, while the benefit of platform switching may depend on implant design, tissue thickness and restorative geometry. Therefore, it is of interest to compare the peri-implant crestal bone loss around platform-switched and platform-matched implants during the first year of functional loading in 60 participants randomized equally between the two restoration designs. Standardized digital periapical radiographs were obtained at prosthesis delivery, 6 months and 12 months and mesial/distal marginal bone levels, probing depth, bleeding on probing and implant survival were evaluated. Mean 12-month marginal bone loss was 0.58 ± 0.24 mm with platform switching and 1.12 ± 0.35 mm with platform matching (p<0.001); the difference remained significant after adjustment for implant site, mucosal thickness and insertion depth, while implant survival was 100% and 96.7%, respectively. Thus, platform switching was associated with high preservation of crestal bone during the first year of loading, while peri-implant soft-tissue outcomes were comparable. |
|
Keywords |
Platform switching, platform matching, marginal bone loss, dental implant, crestal bone, radiographic study
|
|
Citation |
Gohil et al. Bioinformation 22(8): 5471-5474 (2026)
|
|
Edited by |
Hiroj Bagde
|
|
ISSN |
0973-2063
|
|
Publisher |
|
|
License |
This is an Open Access article which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. This is distributed under the terms of the Creative Commons Attribution License.
|
|
|
|