Title |
Dentin loss and fracture resistance after ultrasonic retrieval of separated NiTi instruments
|
|
Authors |
Dhruval Acharya1, Lavanshi Mishra2, Jasmine Marwaha3,*, Suchismita
Chakraborty4, Vipin
|
|
Affiliation |
1Department of Oral and Maxillofacial Pathology, K. M. Shah Dental College and Hospital, Sumandeep Vidyapeeth Deemed to be University, Gujarat, India; 2Department of Conservative Dentistry and Endodontics, Modern Dental College and Research Centre, Indore, India; 3Department of Conservative Dentistry and Endodontics, National Dental College and Hospital, Derabassi, Punjab, India; 4Department of Conservative Dentistry and Endodontics, Guwahati, Assam, India; 5Department of Restorative Dental Sciences, Faculty of Dentistry, Taif University, Taif, Kingdom of Saudi Arabia; 6Department of Conservative Dentistry & Endodontics, Maharishi Markandeshwar College of Dental Sciences & Research, Mullana, Haryana, India; *Corresponding author
|
|
|
Dhruval Acharya - E-mail: acharyadhruval@gmail.com
|
|
Article Type |
Research Article
|
|
Date |
Received September 1, 2026; Revised
September 30, 2026; Accepted September 30, 2026, Published September
30, 2026 |
|
Abstract |
Retrieval of separated nickel-titanium instruments may preserve endodontic treatment options, but excessive dentin removal can weaken the root and reduce fracture resistance. This in vitro study used micro-computed tomography and universal testing machine analysis to compare dentin loss and fracture resistance after retrieval with different ultrasonic retrieval systems. Eighty extracted single-rooted mandibular premolars with standardized root dimensions were allocated to conventional ultrasonic tip, micro ultrasonic tip, and loop-assisted ultrasonic retrieval and control groups. Retrieval success was highest with loop-assisted ultrasonic retrieval (90.0%), while dentin volume loss was lowest with micro-ultrasonic tips (3.8 ± 1.1 mm³) and fracture resistance was significantly reduced after conventional ultrasonic retrieval compared with controls (412.6 ± 84.7 N vs 586.4 ± 92.3 N; p<0.001). Thus, ultrasonic retrieval systems differed significantly in dentin preservation and post-retrieval fracture resistance, supporting the need for conservative retrieval protocols guided by three-dimensional assessment. |
|
Keywords |
Micro-CT, separated instrument, ultrasonic retrieval, nickel-titanium file, dentin loss, fracture resistance, endodontics
|
|
Citation |
Acharya et al. Bioinformation 22(9): 5547-5551 (2026)
|
|
Edited by |
Ashwini Dhopte
|
|
ISSN |
0973-2063
|
|
Publisher |
|
|
License |
This is an Open Access article which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. This is distributed under the terms of the Creative Commons Attribution License.
|
|
|
|