HOME   |    PDF   |   


Title

Comparative evaluation of nanoparticles as reinforcing agents on the flexural strength in denture base materials

 

Authors

Vyakhya Agarwal 1,*, Harsh Mahajan 1, Varsha khichi 1, Abhishek Sharma 2, Venus Sepeya 3 & Sandeep Thakur 4

 

Affiliation

1Department of Prosthodontics, People's Dental Academy, Bhopal, Madhya Pradesh, India; 2Department of Prosthodontics, Geetanjali Dental and Research Institute, Geetanjali University, Udaipur, Rajasthan, India; 3Department of Prosthodontics, Dental College Shimla and Hospital, Madhya Pradesh, India; 4Department of Prosthodontics, Rishiraj College of Dental Science, Bhopal, Madhya Pradesh, India; *Corresponding author

 

Email

Vyakhya Agarwal - E-mail: vyakhyaagrawal08@gmail.com
Harsh Mahajan - E-mail: drharshmahajan1008@gmail.com
Varsha Khichi - E-mail: varsha.khichi.21@gmail.com
Abhishek Sharma - E-mail: abhisheks8769@gmail.com
Venus Sepeya - E-mail: angellika05@gmail.com
Sandeep Thakur - E-mail: thakursandeep1206@gmail.com
 

Article Type

Research Article

 

Date

Received October 1, 2026; Revised October 31, 2026; Accepted October 31, 2026, Published October 31, 2026

 

Abstract

A major limitation of conventional PMMA denture base materials is their inherent brittleness and low flexural strength, which frequently leads to midline fractures under clinical masticatory forces. Therefore, it is of interest to compare the flexural strength of PMMA denture base materials reinforced with zirconium oxide, titanium dioxide and boron nitride nanoparticles. Hence, 40 PMMA specimen were divided into 4 groups (n=10), tested using a Universal Testing Machine and analyzed with one way ANOVA and TURKEY' S HSD test (p < 0.05). Zirconium oxide and titanium dioxide significantly improved flexural strength compared with boron nitride and control group. (p < 0.001). Turkey's HSD showed no significant difference between zirconium oxide and titanium oxide while load displacement analysis conform their superior fracture resistance. Thus, zirconium oxide and titanium dioxide are effective PMMA reinforcing agents with zirconium oxide showing the highest overall performance, whereas boron nitride offered very little reinforcement.

 

Keywords

Polymethyl methacrylate (PMMA), Titanium dioxide nanoparticle, silver nanoparticle, boron nitride nanoparticle, colony forming units, probe sonicator

 

Citation

Agarwal et al. Bioinformation 22(10): 6167-6171 (2026)

 

Edited by

Vini Mehta

 

ISSN

0973-2063

 

Publisher

Biomedical Informatics

 

License

This is an Open Access article which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. This is distributed under the terms of the Creative Commons Attribution License.