HOME   |    PDF   |   


Title

Digital inclinometer-guided acetabular cup positioning in total hip arthroplasty: A prospective observational study

 

Authors

Pratham Agrawal, Sparsh Naik, Ashish Sirsikar & Lakhan Singh Maravi*

 

Affiliation

Department of Orthopaedics, Netaji Subhash Chandra Bose Medical College, Jabalpur, Madhya Pradesh, India; *Corresponding author

 

Email

Pratham Agrawal - E-mail: damohpratham151@gmail.com; Phone: +91 7223850498
Sparsh Naik - E-mail: drsparshnaik@gmail.com
Ashish Sirsikar - E-mail: drashishsirsikar@gmail.com
Lakhan Singh Maravi - E-mail: maravidrlakhansingh@gmail.com
 

Article Type

Research Article

 

Date

Received October 1, 2026; Revised October 31, 2026; Accepted October 31, 2026, Published October 31, 2026

 

Abstract

Proper acetabular cup alignment during total hip arthroplasty (THA) is essential to reduce instability, impingement, wear and loosening, but advanced navigation systems are often unavailable because of their cost and limited accessibility. This prospective study evaluated 30 patients undergoing THA between May 2024 and April 2026 using a dual-axis digital inclinometer for intraoperative cup inclination and post-operative radiographic inclination and Harris Hip Score at 6 months were assessed. Post-operative radiographs showed that 27 of 30 hips (90%) were within the Lewinnek safe zone and the mean post-operative inclination angle was significantly lower in the safe group than in the unsafe group (42.34 +/- 3.00° vs. 55.91 +/- 4.26°, p < 0.05). Patients with cup placement within the safe zone had better Harris Hip Scores (86.22 +/- 8.64 vs. 81.00 +/- 6.08), while a weak positive correlation was observed between intraoperative and post-operative inclination measurements (r = 0.360, p = 0.060). Thus, digital inclinometer-assisted cup placement is a simple, practical and cost-effective technique that may improve acetabular cup alignment during THA, particularly in centres without navigation facilities.

 

Keywords

Digital inclinometer, total hip arthroplasty (THA), acetabular cup inclination, lewinnek safe zone, hip replacement

 

Citation

Agrawal et al. Bioinformation 22(10): 6267-6271 (2026)

 

Edited by

Vini Mehta

 

ISSN

0973-2063

 

Publisher

Biomedical Informatics

 

License

This is an Open Access article which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. This is distributed under the terms of the Creative Commons Attribution License.