HOME   |    PDF   |   


Title

Comparative evaluation of compressive and diametral tensile strength: Nanoceramic versus conventional composite resins

 

Authors

Prasad Chandrakant Ingale1, Anjali Sharma 2, Srividya Putchha 3, Mahesh Hiregoudar 4, Devna Sharma 5, Barkha Idnani 6 & Pratik Surana 7,*

 

Affiliation

1Department of Conservative Dentistry and Endodontics, Bharati Vidyapeeth (Deemed to be University) Dental College and Hospital, Sangli, Maharashtra, India; 2Department of Conservative Dentistry and Endodontics, TMDC & RC, Moradabad, Uttar Pradesh, India; 3Department of General Dentistry, University of Pennsylvania, 240 S 40th Street, Philadelphia, United States of America; 4Department of Public Health Dentistry, P.M.N.M Dental College & Hospital, Bagalkote, Karnataka, India; 5Department of Conservative Dentistry and Endodontics, Faculty of Dental Sciences, SGT University, Budheda, Gurgaon, Haryana, India; 6Department of Conservative Dentistry and Endodontics, Faculty of Dental Sciences, Dharmsinh Singh Desai University, Nadiad, Gujarat, India; 7Department of Pedodontics and Preventive Dentistry, Maitri College of Dentistry and Research Centre, Durg, Chhattisgarh, India; *Corresponding author

 

Email

Prasad Chandrakant Ingale - E-mail: prasadingale99@gmail.com; Phone: +91 9822424131
Anjali Sharma - E- mail: anjali357512@gmail.com; Phone: +91 7017996796
Srividya Putchha - E-mail: srividya1011@gmail.com; Phone: +91 7207718480
Mahesh Hiregoudar - E-mail: maheshiregoudar@gmail.com; Phone: +91 9886438541
Devna Sharma - E-mail: drdevna_fds@sgtuniversity.org; Phone: +91 9557472277
Barkha Idnani - E-mail: barkhaidnani@gmail.com; Phone: +91 9998507485
Pratik Surana - E-mail: suranadrpratik@gmail.com; Phone: +91 8871310111
 

Article Type

Research Article

 

Date

Received October 1, 2026; Revised October 31, 2026; Accepted October 31, 2026, Published October 31, 2026

 

Abstract

Advanced filler technologies in composite resins aim to improve mechanical performance and clinical durability. Therefore, it is of interest to compare the compressive strength and diametral tensile strength of nanoceramic and conventional composite resin materials. Two groups were evaluated: Group A, Neo Spectra ST nanoceramic composite and Group B, Filtek Z250 XT. Twenty specimens each for CS (6 × 3 mm) and DTS (6 × 12 mm) were tested using a universal testing machine. Thus, the nanoceramic composite showed higher CS and DTS than conventional composite resin, indicating superior mechanical performance.

 

Keywords

Nanoceramic composite, conventional composite resin, compressive strength, diametral tensile strength

 

Citation

Ingale et al. Bioinformation 22(10): 6500-6503 (2026)

 

Edited by

P Kangueane

 

ISSN

0973-2063

 

Publisher

Biomedical Informatics

 

License

This is an Open Access article which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. This is distributed under the terms of the Creative Commons Attribution License.