HOME   |    PDF   |   


Title

Cord vs NoCord™ VPS retraction: Effects on gingival displacement, gingival health and impression quality

 

Authors

Ankita Kumari 1,*, Daya Shankar 1, Souvir Mohan Pandey 1, Nandita Biswas 2, Shreya Mukherjee 1 & Shouvik Ghosh 1

 

Affiliation

1Department of Prosthodontics and Crown and Bridge, Hazaribag college of Dental Sciences and Hospital, Hazaribagh, Jharkhand, India; 2Department of Prosthodontics and Crown and Bridge, Kusum Devi Sunderlal Dugar Jain Dental College and Hospital, Kolkata, West Bengal, India; *Corresponding author

 

Email

Ankita Kumari - E-mail: ankitagupta0595@gmail.com; Phone: +91 8890770828
Daya Shankar - E-mail: drdaya56@gmail.com; Phone: +91 9097760927
Souvir Mohan Pandey - E-mail: souvir.pandey@yahoo.com; Phone: +91 9634904887
Nandita Biswas - E-mail: dr.nandita.biswas@gmail.com; Phone: +91 7000904430
Shreya Mukherjee - E-mail: mukherjeeshreya94@gmail.com; Phone: +91 7003619914
Shouvik Ghosh -E-mail: dr.shouvik1998@gmail.com; Phone: +91 8674962668
 

Article Type

Research Article

 

Date

Received October 1, 2026; Revised October 31, 2026; Accepted October 31, 2026, Published October 31, 2026

 

Abstract

Accurate reproduction of subgingival finish lines remains challenging in fixed prosthodontics because conventional gingival retraction is technique-sensitive and may cause soft tissue trauma. This split-mouth clinical study evaluated 34 patients requiring anterior full-coverage restorations by comparing NoCord vinyl polysiloxane with SURE-Cord knitted retraction cord for gingival displacement, health, patient comfort and impression quality. SURE-Cord achieved significantly greater horizontal and vertical displacement, whereas NoCord vinyl polysiloxane produced less immediate post-operative inflammation and greater patient comfort (p < 0.05). Gingival health returned toward baseline within 7 days with both techniques, indicating comparable overall clinical performance. Thus, data support NoCord vinyl polysiloxane as a simplified, tissue-friendly alternative to conventional cord retraction for fixed prosthodontic impressions.

 

Keywords

Gingival retraction, NoCord VPS, retraction cord, vinyl polysiloxane, gingival displacement, gingival index, prosthodontics, impression quality

 

Citation

Kumari et al. Bioinformation 22(10): 6589-6595 (2026)

 

Edited by

Vini Mehta

 

ISSN

0973-2063

 

Publisher

Biomedical Informatics

 

License

This is an Open Access article which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. This is distributed under the terms of the Creative Commons Attribution License.