HOME   |    PDF   |   


Title

Comparison of 3D printed versus CAD-CAM milled surgical guides on implant placement precision

 

Authors

Rasika Avinash Kulkarni 1,*, Shaili Agarwal 2, Megha Sharma 3, Swati Solanki 4, Manjiri Salkar 5 & Sumbul Saifi 6

 

Affiliation

1Department of Prosthodontics and Crown & Bridge, SMBT Dental College & Hospital, Ghulewadi (Amrutnagar), Sangamner, Ahmednagar, Maharashtra, India; 2Department of Prosthodontics, Crown & Bridge, Daswani Dental College, Kota, Rajasthan, India; 3Department of Periodontology & Oral Implantology, Swami Devi Dayal Hospital & Dental College, Golpura, Barwala, Panchkula, Haryana, India; 4Department of Prosthodontics, Crown and Bridge, Government College of Dentistry, Indore, Madhya Pradesh, India; 5Department of Prosthodontics, MGV's KBH Dental College and Hospital, Nashik, Maharashtra, India; 6Department of Periodontology and Implantology, Institute of Dental Sciences, Bareilly, Uttar Pradesh, India; *Corresponding author

 

Email

Rasika Avinash Kulkarni - E-mail: rasikakul1705@gmail.com
Shaili Agarwal - E-mail: drshaili90@gmail.com
Megha Sharma - E-mail: meghadr92@gmail.com
Swati Solanki - E-mail: swatipcds@gmail.com
Manjiri Salkar - E-mail: drmanjirisalkar@gmail.com
Sumbul Saifi - E-mail: dr.sumbulsaifi@gmail.com
 

Article Type

Research Article

 

Date

Received October 1, 2026; Revised October 31, 2026; Accepted October 31, 2026, Published October 31, 2026

 

Abstract

Inaccurate implant placement remains a major challenge in implant dentistry, compromising functional and aesthetic outcomes despite advances in guided surgery. Therefore, it is of interest to evaluate the implant placement accuracy using 3D-printed resin and CAD-CAM milled surgical guides in 40 implant sites, assessing angular, coronal, apical and depth deviations. Both guide types achieved clinically acceptable accuracy, but CAD-CAM milled guides showed significantly lower angular, coronal and apical deviations (p ≤ 0.001), with no significant difference in depth deviation. The superior performance of milled guides was attributed to the greater dimensional stability of pre-polymerized blocks compared with layer-by-layer resin printing. Thus, data shows that guide manufacturing technique significantly influences implant placement accuracy, supporting evidence-based optimisation of digital workflows and surgical guide selection in implant dentistry.

 

Keywords

Dental implants, guided implant surgery, 3D-printed surgical guides, CAD-CAM milled guides; implant placement accuracy, angular deviation, digital dentistry

 

Citation

Kulkarni et al. Bioinformation 22(10): 6606-6609 (2026)

 

Edited by

Ritik Kashwani

 

ISSN

0973-2063

 

Publisher

Biomedical Informatics

 

License

This is an Open Access article which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. This is distributed under the terms of the Creative Commons Attribution License.