Title

Comparison of shear bond strength and microleakage between bioactive restorative material and self-adhesive bulk fill composite - An in vitro study

 

Authors

Mithila Mohan1,*, D.S Dinesh1, Bindu Meera John2, A. Karthikeyan1, Poorani Durai1, 2 & Hema
Pulidindi3

 

Affiliation

1Department of Conservative Dentistry and Endodontics, Sri Venkateshwaraa Dental College (Affiliated to Pondicherry University), Ariyur, Puducherry, India; 2Department of Conservative Dentistry and Endodontics, Indira Gandhi Institute of Dental Sciences, Sri Balaji Vidyapeeth (Deemed to be University), Puducherry, India; 3Department of Conservative Dentistry and Endodontics, KIMS Dental College and Hospital, Amalapuram, Andhra Pradesh, India; *Corresponding author

 

Email

Mithila Mohan - E-mail: mithilamithss@gmail.com; Phone: +91 9400778859
D.S Dinesh - E-mail: drdinesh.d.s@gmail.com; Phone: +91 9443459210
Bindu Meera John - E-mail: bindumeerajohn@igids.ac.in; Phone: +91 9443021768
A. Karthikeyan - E-mail: dr.akarthikeyan@gmail.com; Phone: +91 9943303369
Poorani Durai - E-mail: pooranidurai007@gmail.com; Phone: +91 9087603430
Hema Pulidindi - E-mail: hema.pulidindi2009@gmail.com; Phone: +91 7382484912

 

Article Type

Research Article

 

Date

Received October 1, 2026; Revised October 31, 2026; Accepted October 31, 2026, Published October 31, 2026

 

Abstract

Achieving reliable resin–dentin bonding with minimal microleakage remains a challenge for contemporary restorative materials. Therefore, it is of interest to evaluate the shear bond strength, microleakage and resin–dentin hybrid layer of a bioactive restorative material, a self-adhesive bulk-fill composite and conventional composites using 64 extracted human teeth. Tetric N-Ceram Bulk-Fill demonstrated the highest shear bond strength (25.90 +/-  0.23 MPa) and resin penetration depth (12.91 +/- 0.20 μm), with minimal microleakage. SureFil one showed the lowest bond strength and resin penetration, with predominantly severe microleakage (all p < 0.001). The findings indicate superior bonding and marginal integrity with the bulk-fill composite compared with the self-adhesive material. Thus, data shows the importance of effective adhesive-mediated resin penetration for durable resin–dentin bonding.

 

Keywords

Shear bond strength, microleakage, bioactive restorative material, bulk-fill composite, confocal laser scanning microscopy

 

Citation

Mohan et al. Bioinformation 22(10): 7090-7093 (2026)

 

Edited by

Ritik Kashwani

 

ISSN

0973-2063

 

Publisher

Biomedical Informatics

 

License

This is an Open Access article which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. This is distributed under the terms of the Creative Commons Attribution License.