HOME   |    PDF   |   


Title

Fracture resistance of screw-retained implant crowns using different restorative materials

 

Authors

Sameer Chauhan1,*, Ankit Malu2, Nida Malik3, Bhagyashree P. Agre4, Sumathi K. Nitin5 & Saba Malik6

 

Affiliation

1Department of Prosthodontics and Crown & Bridge, K. M. Shah Dental College and Hospital, Sumandeep Vidyapeeth (Deemed to be University), Pipariya, Waghodia, Vadodara, Gujarat 391760, India; 2Department of Oral and Maxillofacial Surgery, Deenanath Mangeshkar Hospital, Pune, Maharashtra 411037, India; 3Department of Periodontology, Govt. Kamla Nehru Hospital, Bhopal, Madhya Pradesh 462001, India; 4Department of Public Health Dentistry, Bharati Vidyapeeth (Deemed to be University) Dental College and Hospital, Pune, Maharashtra, India; 5Department of Prosthodontics and Crown & Bridge, Hitkarini Dental College & Hospital, Jabalpur 482002, Madhya Pradesh, India; 6Department of Periodontology, Dental Clinic and Research Centre, Bhopal, Madhya Pradesh 462002, India; *Corresponding author

 

Email

Sameer Chauhan - E-mail: csameer309@gmail.com
Ankit Malu - E-mail: ankitmalu@gmail.com
Nida Malik - E-mail: drnidamalik05@gmail.com
Bhagyashree P. Agre - E-mail: bhagyashree.agre@bharatividyapeeth.edu
Sumathi K. Nitin - E-mail: nitinsumathi@yahoo.com
Saba Malik - E-mail: saba.taurus@gmail.com
 

Article Type

Research Article

 

Date

Received October 1, 2026; Revised October 31, 2026; Accepted October 31, 2026, Published October 31, 2026

 

Abstract

Screw-retained implant crowns require restorative materials with adequate fracture resistance and predictable failure behaviour for long-term clinical success. Therefore, it is of interest to evaluate the fracture resistance and failure modes of 40 crowns fabricated from metal-ceramic, monolithic zirconia, lithium disilicate and polymer-infiltrated ceramic network (PICN) (n = 10/group). After thermocycling and cyclic mechanical loading, specimens underwent fracture testing and microscopic failure analysis. Monolithic zirconia exhibited the highest fracture resistance, followed by metal-ceramic, lithium disilicate and PICN, with statistically significant differences between all groups. Thus, restorative material influences fracture resistance and failure patterns, supporting material selection according to anticipated occlusal loads and clinical requirements.

 

Keywords

Dental implants, screw-retained crown, fracture resistance, restorative materials, monolithic zirconia, lithium disilicate, titanium base abutment

 

Citation

Chauhan et al. Bioinformation 22(10): 7188-7191 (2026)

 

Edited by

Ruby Singh

 

ISSN

0973-2063

 

Publisher

Biomedical Informatics

 

License