HOME   |    PDF   |   


Title

Dental implant hemocompatibility: Comparison of two surface treatments

 

Authors

Shyju Prasad Suresh Babu1, Giri Chandramohan2, Aparna Mohan2,*, Junu Henry2, Allen Jim Hines2 & Celin Joel Chelladhurai2

 

Affiliation

1Department of Prosthodontics and Crown & Bridge, Thampy's S.P. Dental Clinic, Nagercoil, Kanyakumari, Tamil Nadu, India; 2Department of Prosthodontics, Sree Mookambika Institute of Dental Sciences, Kulasekharam, Tamil Nadu, India; *Corresponding author

 

Email

Shyju Prasad Suresh Babu - E-mail: drshyjuprasad@gmail.com
Giri Chandramohan - E-mail: giritc@yahoo.com
Aparna Mohan - E-mail: aparraj1972@gmail.com
Junu Henry - E-mail: junujubin@gmail.com
Allen Jim Hines - E-mail: hinesjimallen@gmail.com
Celin Joel Chelladhurai - E-mail: joeldhurai@gmail.com
 

Article Type

Research Article

 

Date

Received October 1, 2026; Revised October 31, 2026; Accepted October 31, 2026, Published October 31, 2026

 

Abstract

Implant surface topography can influence the initial blood-surface interaction that precedes osseointegration. Therefore, it is of interest to compare the hemocompatibility of 14 commercially available titanium implants with calcium-phosphate-blasted surfaces (Group I, n=7) or alumina-blasted and acid-etched surfaces (Group II, n=7) using blood-cell counts, platelet measures and platelet adhesion/activation assays. Initial-to-final paired comparisons were not statistically significant in either group (Group I p=0.551; Group II p=0.488), while platelet adhesion/activation was numerically higher for the calcium-phosphate-blasted surface (409.94 +/- 884.62 vs 352.79 +/- 723.63 IU/L). The reported hemolysis values are unusually high for conventional hemocompatibility interpretation and should be verified against the original laboratory calculation and units before submission. Thus, surface-dependent variation in early blood interactions, but the present results do not establish statistically significant superiority of one surface treatment.

 

Keywords

Hemocompatibility, dental implant surface treatments, platelet adhesion and activation

 

Citation

Babu et al. Bioinformation 22(10): 7328-7332 (2026)

 

Edited by

Ashwini Dhopte

 

ISSN

0973-2063

 

Publisher

Biomedical Informatics

 

License

This is an Open Access article which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. This is distributed under the terms of the Creative Commons Attribution License.