Accuracy of electronic apex locator versus radiography for root canal working length: An in vitro study

 

Authors

Joyeeta Mahapatra 1,*, Aditya Patel 2, Nikhil Mankar 3 & Aradhana N. Kibe 4

 

Affiliation

1Department of Dentistry, All India Institute of Medical Sciences, Kalyani, West Bengal, India; 2Department of Conservative Dentistry and Endodontics, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Higher Education and Research (Deemed to be University), Sawangi (Meghe), Wardha, India; 3Department of Conservative Dentistry and Endodontics, Bhabha College of Dental Sciences, Bhopal, Madhya Pradesh, India; 4Department of Conservative Dentistry and Endodontics, Bharati Vidyapeeth (Deemed to be University) Dental College and Hospital, Sangli, Maharashtra, India; *Corresponding author

 

Email

Joyeeta Mahapatra - E-mail: joyeetamahapatra@gmail.com
Aditya Patel - E-mail: adityasinghpatel@gmail.com
Nikhil Mankar - E-mail: nikhilmankar26@gmail.com
Aradhana Kibe - E-mail: aradhanakibe@gmail.com
 

Article Type

Research Article

 

Date

Received October 1, 2026; Revised October 31, 2026; Accepted October 31, 2026, Published October 31, 2026

 

Abstract

Accurate working-length determination is essential for predictable root canal treatment, but the effect of canal curvature on electronic and radiographic measurements remains uncertain. Therefore, it is of interest to compare the electronic apex locator (EAL) and conventional radiography with visually established actual working length (AWL) in 84 extracted teeth allocated equally to straight (≤5°), moderately curved (10-20°) and severely curved (>20-25°) groups. Both methods showed a small systematic underestimation of AWL (overall mean bias approximately -0.53 mm), with 95.2% of measurements within  +/- 0.5 mm and 98.8% within  +/- 1.0 mm; agreement was good to excellent across curvature groups (ICC 0.87-0.95). Absolute error did not differ significantly among curvature groups (ANOVA p = 0.147; Kruskal-Wallis p = 0.160) and curvature severity was not significantly correlated with error (Spearman ρ = 0.068, p = 0.541). Thus, both (EAL) and radiography provided clinically acceptable working-length estimates and increasing canal curvature did not significantly reduce measurement accuracy.

 

Keywords

Electronic apex locator (EAL), working length (WL), root canal curvature, Schneider's method, Bland-Altman analysis, intraclass correlation coefficient, radiography

 