|
Title |
Mechanical durability and dual-species biofilm accumulation in mandibular advancement device materials: An in vitro comparison
|
|
Authors |
Divya Dudulwar 1, Laxman Singh Kaira 2, Pranav R. Kamble 3, Sankhya Ghosh 4, Rangoli Srivastava 5,* & Sadef Naqvi 6
|
|
Affiliation |
1Department of Conservative Dentistry and Endodontics, D Y Patil Dental School, Lohegaon, Pune, India; 2Department of Dentistry, Government Medical College Datia, Madhya Pradesh, India; 3Department of Orthodontics and Dentofacial Orthopedics, Nanded Rural Dental College, Nanded, Maharashtra, India; 4Department of Orthodontics and Dentofacial Orthopaedics, Kusum Devi Sundarlal Dugar Jain Dental College and Hospital, Cossipore, Kolkata, India; 5Department of Public Health Dentistry, Faculty of Dental Sciences, SGT University, Gurugram, Haryana, India; 6Department of Pediatric and Preventive Dentistry, NIMS Dental College, Jaipur, Rajasthan, India; *Corresponding author
|
|
|
Divya Dudulwar - E -mail: divyarachalwar1@gmail.com |
|
Article Type |
Research Article
|
|
Date |
Received October 1, 2026; Revised October 31, 2026; Accepted October 31, 2026, Published October 31, 2026
|
|
Abstract |
Mandibular advancement devices are established non-invasive options for selected adults with obstructive sleep apnoea and their durability depends on both appliance design and material performance. Therefore, it is of interest to compare the conventional heat-polymerized polymethyl methacrylate (PMMA) with a 3D-printed biocompatible appliance resin using 80 specimens allocated to mechanical and surface/biofilm testing. Conventional PMMA showed significantly greater flexural strength and peak load, whereas the printed resin showed greater surface roughness, lower water contact angle and higher Streptococcus mutans-Candida albicans biofilm biomass and viable counts (all major comparisons p ≤ 0.002). Surface roughness was moderately correlated with total biofilm biomass (r = 0.67, p < 0.001). Thus, conventional PMMA was mechanically stronger and accumulated less dual-species biofilm than the evaluated 3D-printed resin, indicating that printing parameters and finishing protocols require careful optimization before material equivalence is assumed. |
|
Keywords |
Mandibular advancement device, obstructive sleep apnoea, three-dimensional printing, polymethyl methacrylate, flexural strength, surface roughness, biofilm
|
|
Citation |
Dudulwar et al. Bioinformation 22(10): 7471-7475 (2026)
|
|
Edited by |
Ashwini Dhopte
|
|
ISSN |
0973-2063
|
|
Publisher |
|
|
License |
This is an Open Access article which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. This is distributed under the terms of the Creative Commons Attribution License.
|
|
|
|