HOME   |    PDF   |   


Title

Assessment of injectable bioactive composite for deep margin elevation: An in vitro study

 

Authors

Priyatam Maruti Karade 1, Jasmine Marwaha 2,*, Anshit Babel 3, Ashtha Arya 4, Vaishali Ulhas Bhalerao 5 & Ramandeep Ramandeep 6

 

Affiliation

1Department of Conservative Dentistry and Endodontics, Bharati Vidyapeeth (Deemed to be University) Dental College and Hospital, Sangli, Maharashtra, India; 2Department of Conservative Dentistry and Endodontics, National Dental College and Hospital, Derabassi, Punjab, India; 3Department of Prosthodontics, Crown and Bridge, Geetanjali Dental and Research Institute, Geetanjali University, Udaipur, Rajasthan, India; 4Department of Conservative Dentistry and Endodontics, SGT Dental College, Hospital and Research Institute, SGT University, Gurugram, Haryana, India; 5Department of Conservative Dentistry and Endodontics, Rural Dental College, Pravara Institute of Medical Sciences (Deemed to be University), Loni Bk., Ahmednagar, Maharashtra, India; 6Department of Conservative Dentistry and Endodontics, Maharishi Markandeshwar College of Dental Sciences & Research, Mullana, Haryana, India; *Corresponding author

 

Email

Priyatam Maruti Karade - E-mail: priyatam.karade@bharatividyapeeth.edu
Jasmine Marwaha - E-mail: drjasminemarwaha@gmail.com
Anshit Babel - E-mail: anshitbabel@gmail.com
Astha Arya - E-mail: drashthaarya@yahoo.co.in
Vaishali Ulhas Bhalerao - E-mail: vaishali.bhalerao@pmtpims.org
Ramandeep Ramandeep - E-mail: renu.malh7@gmail.com
 

Article Type

Research Article

 

Date

Received October 1, 2026; Revised October 31, 2026; Accepted October 31, 2026, Published October 31, 2026

 

Abstract

Deep margin elevation relocates a subgingival proximal margin coronally with an adhesive restorative material before placement of an indirect restoration. Therefore, it is of interest to compare the injectable bioactive composite, a highly filled injectable composite and a flowable bulk-fill composite in 75 standardized mandibular molars restored with adhesively luted lithium-disilicate overlays. After thermomechanical aging, the bioactive group showed the highest continuous-margin percentage and the smallest maximum marginal gap, while microleakage was lower than in the flowable bulk-fill group. Fracture resistance differed modestly among materials, whereas the distribution of repairable and catastrophic failures was not significantly different. Thus, data shows that injectable bioactive composite provided favourable marginal adaptation without compromising fracture resistance.

 

Keywords

Deep margin elevation, cervical margin relocation, bioactive composite, injectable composite, marginal adaptation, microleakage, fracture resistance

 

Citation

Karade et al. Bioinformation 22(10): 7482-7487 (2026)

 

Edited by

Ashwini Dhopte

 

ISSN

0973-2063

 

Publisher

Biomedical Informatics

 

License

This is an Open Access article which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. This is distributed under the terms of the Creative Commons Attribution License.