HOME   |    PDF   |   


Title

Injectable GelMA/nHA scaffold around dental implant surfaces: An in vitro study

 

Authors

Dhruval Acharya 1, Karthikeyan Vasudevan 2,*, Vijay Parmar 3, Jeemee Patel 4, Abhaya Chandra Das 5 & Sunny Mavi 6

 

Affiliation

1Department of Oral and Maxillofacial Pathology, K.M. Shah Dental College and Hospital, Sumandeep Vidyapeeth Deemed to be University, Gujarat, India; 2Department of Prosthodontics, SRM Dental College, Ramapuram, Chennai, Tamil Nadu, India; 3Department of Dentistry, AIIMS Rajkot, Gujarat, India; 4Department of Oral and Maxillofacial Surgery, Siddhpur Dental College and Hospital, Dethali, Patan, Gujarat, India; 5Department of Periodontics and Oral Implantology, Institute of Dental Sciences, Siksha 'O' Anusandhan (Deemed to be University), Bhubaneswar, Odisha, India; 6Department of Periodontics, Sudha Rustagi College of Dental Science and Research, Faridabad, Haryana, India; *Corresponding author

 

Email

Dhruval Acharya - E-mail: acharyadhruval@gmail.com
Karthikeyan Vasudevan - E-mail: drkarthikvasudev@gmail.com
Vijay Parmar - E-mail: vijayparmar8597@gmail.com
Jeemee Patel - E-mail: jeemee.patel2223@gmail.com
Abhaya Chandra Das - E-mail: drabhaya2011@gmail.com
Sunny Mavi - E-mail: snnymavi@gmail.com
 

Article Type

Research Article

 

Date

Received October 1, 2026; Revised October 31, 2026; Accepted October 31, 2026, Published October 31, 2026

 

Abstract

Injectable hydrogels can conform to irregular peri-implant defects, but their mechanical stability and osteogenic behaviour depend on composition and interaction with titanium. Therefore, it is of interest to compare the injectable gelatin-methacryloyl/nano-hydroxyapatite (GelMA/nHA) scaffold with GelMA and collagen controls around sandblasted, acid-etched titanium surfaces. The formulations were assessed for injectability, gelation, swelling, degradation, compressive modulus, cell viability, alkaline phosphatase activity and mineralization using human mesenchymal stromal cells. GelMA/nHA showed higher compressive modulus, lower 28-day mass loss and greater day-14 ALP activity and day-21 mineral deposition than both comparators (p < 0.001), while all groups' maintained viability above 85%. Thus, data support further peri-implant evaluation of GelMA/nHA as an injectable scaffold with favourable handling, structural stability, cytocompatibility and osteogenic activity.

 

Keywords

Injectable scaffold, dental implant, GelMA, nano-hydroxyapatite, tissue engineering, osteogenesis

 